{"id":15538,"date":"2026-11-23T15:46:18","date_gmt":"2026-11-23T07:46:18","guid":{"rendered":"https:\/\/www.linble-coldroom.com\/?p=15538"},"modified":"2026-11-23T16:31:03","modified_gmt":"2026-11-23T08:31:03","slug":"10-tonluk-bir-soguk-oda-gunde-ne-kadar-elektrik-tuketir","status":"publish","type":"post","link":"https:\/\/www.linble-coldroom.com\/tr\/10-tonluk-bir-soguk-oda-gunde-ne-kadar-elektrik-tuketir\/","title":{"rendered":"10 tonluk bir so\u011fuk oda g\u00fcnde ne kadar elektrik t\u00fcketir?"},"content":{"rendered":"<p>10 tonluk bir so\u011fuk oda, so\u011futulmu\u015f mu yoksa dondurulmu\u015f mu \u00fcr\u00fcnler depolad\u0131\u011f\u0131na ba\u011fl\u0131 olarak \u00e7ok farkl\u0131 miktarlarda elektrik t\u00fcketebilir. \u00d6nemli olan rakam, kompres\u00f6r\u00fcn beygir g\u00fcc\u00fc de\u011fil, tesisat\u0131n tamam\u0131n\u0131n g\u00fcnl\u00fck kWh t\u00fcketimidir.<\/p>\n<p>Bu k\u0131lavuz, her ikisi de 10.000 kg \u00fcr\u00fcn depolayan +5\u00b0C&#8217;lik bir so\u011futucu ve \u221218\u00b0C&#8217;lik bir dondurucu i\u00e7in so\u011fuk oda elektrik t\u00fcketimini hesaplamaktad\u0131r. Her say\u0131sal \u00f6rnek, LINBLE saha \u00f6l\u00e7\u00fcmlerini de\u011fil, belirtilen varsay\u0131mlar\u0131 kullanmaktad\u0131r.<\/p>\n<h2>10 Ton ve Depolama Kapasitesini Tan\u0131mlay\u0131n<\/h2>\n<p>Burada 10 ton, 10 ton so\u011futma kapasitesine (TR) sahip bir so\u011futma tesisi de\u011fil, depolanan 10 metrik ton (10.000 kg) \u00fcr\u00fcn anlam\u0131na gelir. Bir TR, yakla\u015f\u0131k 3,517 kW so\u011futma kapasitesine e\u015fittir; dolay\u0131s\u0131yla 10 TR, 35,17 kW \u0131s\u0131 giderimi anlam\u0131na gelir; 35,17 kW elektrik t\u00fcketimi anlam\u0131na gelmez.<\/p>\n<p>Depolama k\u00fctlesi oda boyutunu belirlemez; istifleme, koridorlar ve hava ak\u0131\u015f\u0131 a\u00e7\u0131kl\u0131\u011f\u0131 \u00f6nemlidir. 6 m \u00d7 4 m \u00d7 3 m boyutlar\u0131nda bir i\u00e7 oda (72 m\u00b3) oldu\u011funu varsayal\u0131m.<\/p>\n<table>\n<tbody>\n<tr>\n<td>Tasar\u0131m girdileri<\/td>\n<td>+5 \u00b0C so\u011futulmu\u015f oda<\/td>\n<td>\u221218\u00b0C dondurucu<\/td>\n<\/tr>\n<tr>\n<td>\u00dcr\u00fcn kapasitesi<\/td>\n<td>10.000 kg<\/td>\n<td>10.000 kg<\/td>\n<\/tr>\n<tr>\n<td>\u0130\u00e7 hacim<\/td>\n<td>72 m\u00b3<\/td>\n<td>72 m\u00b3<\/td>\n<\/tr>\n<tr>\n<td>\u00c7evre s\u0131cakl\u0131\u011f\u0131<\/td>\n<td>30 \u00b0C<\/td>\n<td>30 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Varsay\u0131lan etkin yal\u0131t\u0131m U de\u011feri<\/td>\n<td>0,23 W\/m\u00b2\u00b7K<\/td>\n<td>0,16 W\/m\u00b2\u00b7K<\/td>\n<\/tr>\n<tr>\n<td>Kap\u0131 kullan\u0131m\u0131<\/td>\n<td>G\u00fcnde 12 kez a\u00e7\u0131lma, her seferinde 45 saniye<\/td>\n<td>Ayn\u0131<\/td>\n<\/tr>\n<tr>\n<td>\u00dcr\u00fcn\u00fcn teslim al\u0131nd\u0131\u011f\u0131 durum<\/td>\n<td>Zaten +5 \u00b0C civar\u0131nda<\/td>\n<td>Zaten \u221218\u00b0C civar\u0131nda donmu\u015f<\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015ft\u0131rma ve faturaland\u0131rma<\/td>\n<td>24 saatlik oda, 30 g\u00fcnl\u00fck ay<\/td>\n<td>Ayn\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Varsay\u0131m s\u0131n\u0131r\u0131:<\/strong> Bu basitle\u015ftirilmi\u015f \u0131s\u0131 kazanc\u0131 kontrol\u00fc i\u00e7in t\u00fcm muhafaza y\u00fczeyleri 30\u00b0C&#8217;ye maruz kalm\u0131\u015f olarak kabul edilir. Ger\u00e7ek zemin s\u0131cakl\u0131klar\u0131, \u0131s\u0131 k\u00f6pr\u00fcleri ve nem i\u00e7in ayr\u0131 kontroller gereklidir. Bu, ilk so\u011futma veya g\u0131da dondurma de\u011fil, depolamad\u0131r.<\/p>\n<p>H\u0131zl\u0131 bir kontrol olarak, alt\u0131 oda y\u00fczeyinin toplam alan\u0131 108 m\u00b2&#8217;dir. \u0130letken \u0131s\u0131 kazanc\u0131 yakla\u015f\u0131k olarak \u015fu \u015fekilde hesaplanabilir:<\/p>\n<p><strong>\u0130letim \u0131s\u0131s\u0131 (kWh termal\/g\u00fcn) = U \u00d7 alan \u00d7 s\u0131cakl\u0131k fark\u0131 \u00d7 24 \u00f7 1.000<\/strong><\/p>\n<p>Bu hesaplama, so\u011futucu i\u00e7in 14,90 kWh termal\/g\u00fcn ve dondurucu i\u00e7in 19,91 kWh termal\/g\u00fcn de\u011ferini vermektedir. Bunlar termal y\u00fcklerdir, elektrik t\u00fcketimi de\u011fildir; s\u0131z\u0131nt\u0131 ve i\u00e7 ekipmanlar daha fazla \u0131s\u0131 ekler. ASHRAE\u2019nin <a href=\"https:\/\/handbook.ashrae.org\/handbooks\/R18\/SI\/R18_Ch24\/r18_ch24_si.aspx\"><u>so\u011futmal\u0131 tesis y\u00fck k\u0131lavuzu<\/u><\/a>, gerekli so\u011futma kapasitesini hesaplarken bu kaynaklar\u0131 birbirinden ay\u0131r\u0131r.<\/p>\n<p>Ekipman boyutland\u0131rmas\u0131n\u0131n tamam\u0131 i\u00e7in LINBLE\u2019\u0131n <a href=\"https:\/\/www.linble-coldroom.com\/tr\/how-to-calculate-the-refrigeration-capacity-needed-for-a-cold-room-2\/\"><u>so\u011fuk oda so\u011futma kapasitesi hesaplama k\u0131lavuzunu<\/u><\/a> kullan\u0131n. Elektrik t\u00fcketimi, daha sonra yap\u0131lacak ekipman se\u00e7imine ve \u00e7al\u0131\u015fma s\u00fcresine ba\u011fl\u0131d\u0131r.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-15493\" src=\"https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Split-Running-Loads-by-Equipment.webp\" alt=\"Split Running Loads by Equipment\" width=\"900\" height=\"600\" srcset=\"https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Split-Running-Loads-by-Equipment.webp 900w, https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Split-Running-Loads-by-Equipment-300x200.webp 300w, https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Split-Running-Loads-by-Equipment-768x512.webp 768w, https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Split-Running-Loads-by-Equipment-600x400.webp 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/p>\n<h2>Ekipmanlara G\u00f6re \u00c7al\u0131\u015fma Y\u00fcklerini Ay\u0131rma<\/h2>\n<p>Bir so\u011fuk odan\u0131n g\u00fc\u00e7 t\u00fcketimi tahmini i\u00e7in her bir bile\u015fenin g\u00fcc\u00fc ve \u00e7al\u0131\u015fma saatleri gereklidir. Bir buz \u00e7\u00f6zme \u0131s\u0131t\u0131c\u0131s\u0131 aral\u0131kl\u0131 olarak \u00e7al\u0131\u015f\u0131r; bir kap\u0131 \u00e7er\u00e7evesi \u0131s\u0131t\u0131c\u0131s\u0131 ise s\u00fcrekli \u00e7al\u0131\u015fabilir.<\/p>\n<p>A\u015fa\u011f\u0131daki de\u011ferler, y\u00f6ntemi a\u00e7\u0131klamak amac\u0131yla se\u00e7ilmi\u015f varsay\u0131msal ekipman girdileri ve \u00e7al\u0131\u015fma programlar\u0131d\u0131r. Bunlar, nominal veya garantili t\u00fcketim rakamlar\u0131 de\u011fildir.<\/p>\n<table>\n<tbody>\n<tr>\n<td>Ekipman<\/td>\n<td>So\u011futucu: kW \u00d7 saat\/g\u00fcn<\/td>\n<td>So\u011futucu: kWh\/g\u00fcn<\/td>\n<td>Dondurucu: kW \u00d7 saat\/g\u00fcn<\/td>\n<td>Dondurucu: kWh\/g\u00fcn<\/td>\n<\/tr>\n<tr>\n<td>Sadece kompres\u00f6r<\/td>\n<td>2,40 \u00d7 8<\/td>\n<td>19,20<\/td>\n<td>3,40 \u00d7 13<\/td>\n<td>44,20<\/td>\n<\/tr>\n<tr>\n<td>Kondenser fanlar\u0131<\/td>\n<td>0,25 \u00d7 8<\/td>\n<td>2,00<\/td>\n<td>0,30 \u00d7 13<\/td>\n<td>3,90<\/td>\n<\/tr>\n<tr>\n<td>Evaporat\u00f6r fanlar\u0131<\/td>\n<td>0,22 \u00d7 24<\/td>\n<td>5,28<\/td>\n<td>0,32 \u00d7 22,5<\/td>\n<td>7,20<\/td>\n<\/tr>\n<tr>\n<td>LED ayd\u0131nlatma<\/td>\n<td>0,08 \u00d7 5<\/td>\n<td>0,40<\/td>\n<td>0,08 \u00d7 5<\/td>\n<td>0,40<\/td>\n<\/tr>\n<tr>\n<td>Elektrikli buz \u00e7\u00f6zme<\/td>\n<td>\u00c7al\u0131\u015fma d\u0131\u015f\u0131; 0<\/td>\n<td>0,00<\/td>\n<td>2,40 \u00d7 1,5<\/td>\n<td>3,60<\/td>\n<\/tr>\n<tr>\n<td>Kap\u0131 \u00e7er\u00e7evesi \u0131s\u0131tma<\/td>\n<td>Yok; 0<\/td>\n<td>0,00<\/td>\n<td>0,12 \u00d7 24<\/td>\n<td>2,88<\/td>\n<\/tr>\n<tr>\n<td>Kontroller ve alarmlar<\/td>\n<td>0,04 \u00d7 24<\/td>\n<td>0,96<\/td>\n<td>0,04 \u00d7 24<\/td>\n<td>0,96<\/td>\n<\/tr>\n<tr>\n<td>G\u00fcnl\u00fck toplam<\/td>\n<td><\/td>\n<td>27,84<\/td>\n<td><\/td>\n<td>63,14<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>So\u011futucu, elektrikli \u0131s\u0131t\u0131c\u0131 i\u00e7ermeyen varsay\u0131lan bir \u00e7evrim d\u0131\u015f\u0131 defrost d\u00fczenlemesi kullan\u0131r. Dondurucunun evaporat\u00f6r fanlar\u0131n\u0131n, toplam 1,5 saatlik g\u00fcnl\u00fck elektrikli defrost s\u00fcresi boyunca kapal\u0131 oldu\u011fu varsay\u0131l\u0131r; kompres\u00f6r\u00fcn \u00e7al\u0131\u015fma s\u00fcresi, defrost s\u00fcresinden ayr\u0131d\u0131r. Ger\u00e7ek defrost kontrolleri ve fan gecikmeleri de\u011fi\u015fiklik g\u00f6sterebilir.<\/p>\n<p>\u00c7ift hesaplamadan ka\u00e7\u0131n\u0131n. Bu tabloda, kompres\u00f6r giri\u015fi, ayr\u0131 olarak listelenen kondenser fanlar\u0131n\u0131 i\u00e7ermez. Bir tedarik\u00e7i, kondenser \u00fcnitesinin toplam giri\u015f g\u00fcc\u00fcn\u00fc belirtirse, fan enerjisini tekrar eklemeden \u00f6nce bunun hangi motorlar\u0131 i\u00e7erdi\u011fini kontrol edin. kW cinsinden so\u011futma kapasitesi, kW cinsinden kompres\u00f6r elektrik giri\u015fi ve kWh cinsinden enerji, \u00fc\u00e7 farkl\u0131 b\u00fcy\u00fckl\u00fckt\u00fcr.<\/p>\n<p>\u0130\u00e7 fan motorlar\u0131, lambalar ve elektrikli buz \u00e7\u00f6zme de so\u011futma sisteminin uzakla\u015ft\u0131rmas\u0131 gereken \u0131s\u0131 yayar. Bunlar\u0131n do\u011frudan elektrik t\u00fcketimi (kWh) ekipman tablosuna dahil edilir; ortaya \u00e7\u0131kan termal y\u00fck ise kompres\u00f6r \u00e7al\u0131\u015fma saatlerinin belirlenmesine yard\u0131mc\u0131 olur. Bu, \u00e7ift faturaland\u0131rma de\u011fildir: ancak s\u00f6z konusu \u0131s\u0131, kompres\u00f6r \u00e7al\u0131\u015fma s\u00fcresine zaten yans\u0131t\u0131lm\u0131\u015f olmas\u0131na ra\u011fmen, bu \u0131s\u0131y\u0131 uzakla\u015ft\u0131rmak i\u00e7in ba\u015fka bir elektrik \u00fccreti eklerseniz, bu durum \u00e7ift hesaplama haline gelir.<\/p>\n<p>Wisconsin \u00dcniversitesi Uzmanl\u0131k Merkezi\u2019nin <a href=\"https:\/\/fyi.extension.wisc.edu\/cropstorage\/energy-use-estimator\/\"><u>walk-in so\u011futucu enerji hesaplay\u0131c\u0131s\u0131<\/u><\/a> da, tesise \u00f6zg\u00fc varsay\u0131mlar\u0131 dikkate al\u0131rken, so\u011futma, sirk\u00fclasyon fanlar\u0131 ve ayd\u0131nlatmay\u0131 ayr\u0131 etkenler olarak ele al\u0131r.<\/p>\n<h2>G\u00fcnl\u00fck kWh ve Ayl\u0131k \u0130\u015fletme Maliyetini Hesaplay\u0131n<\/h2>\n<p>Temel so\u011fuk oda i\u015fletme maliyeti hesaplay\u0131c\u0131s\u0131 \u00fc\u00e7 denkleme ihtiya\u00e7 duyar:<\/p>\n<p><strong>G\u00fcnl\u00fck elektrik (kWh) = \u03a3 [ekipman giri\u015fi (kW) \u00d7 g\u00fcnl\u00fck \u00e7al\u0131\u015fma saati]<\/strong><\/p>\n<p><strong>Ayl\u0131k elektrik t\u00fcketimi (kWh) = g\u00fcnl\u00fck kWh \u00d7 g\u00fcn say\u0131s\u0131<\/strong><\/p>\n<p><strong>Ayl\u0131k enerji \u00fccreti = ayl\u0131k kWh \u00d7 kWh ba\u015f\u0131na tarife<\/strong><\/p>\n<p>Varsay\u0131msal olarak 0,15 ABD dolar\u0131\/kWh sabit elektrik fiyat\u0131 ve 30 g\u00fcnl\u00fck bir ay kullan\u0131ld\u0131\u011f\u0131nda sonu\u00e7 \u015f\u00f6yle olur:<\/p>\n<table>\n<tbody>\n<tr>\n<td>Hesaplama<\/td>\n<td>+5\u00b0C so\u011futucu<\/td>\n<td>\u221218\u00b0C dondurucu<\/td>\n<\/tr>\n<tr>\n<td>So\u011fuk oda g\u00fcnl\u00fck kWh<\/td>\n<td>27,84<\/td>\n<td>63,14<\/td>\n<\/tr>\n<tr>\n<td>So\u011fuk oda ayl\u0131k kWh<\/td>\n<td>835,20<\/td>\n<td>1.894,20<\/td>\n<\/tr>\n<tr>\n<td>G\u00fcnl\u00fck enerji \u00fccreti<\/td>\n<td>4,18 ABD dolar\u0131<\/td>\n<td>9,47 ABD dolar\u0131<\/td>\n<\/tr>\n<tr>\n<td>Ayl\u0131k enerji \u00fccreti<\/td>\n<td>125,28 ABD dolar\u0131<\/td>\n<td>284,13 ABD dolar\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00d6rne\u011fin, so\u011futucu elektrik t\u00fcketimi 27,84 \u00d7 30 = 835,20 kWh\/ay ise, 835,20 \u00d7 0,15 $ = 125,28 $\/ay olur. Yerel tarifenizi kullan\u0131n.<\/p>\n<p>Bu rakamlara talep \u00fccretleri, sabit \u00fccretler, vergiler, g\u00fc\u00e7 fakt\u00f6r\u00fc cezalar\u0131, yedek jenerat\u00f6r ve di\u011fer tesis y\u00fckleri dahil de\u011fildir. Bunlar ger\u00e7ek faturalar veya 10 tonluk bir so\u011fuk hava deposu i\u00e7in evrensel bir elektrik t\u00fcketimi referans de\u011feri de\u011fildir.<\/p>\n<p>Kompres\u00f6r \u00e7al\u0131\u015fma programlar\u0131n\u0131n da m\u00fchendislik a\u00e7\u0131s\u0131ndan kontrol edilmesi gerekir. So\u011futucu \u00e7al\u0131\u015f\u0131rken varsay\u0131lan 5,0 kW net so\u011futma kapasitesi sa\u011fl\u0131yorsa, sekiz saatte 40 kWh \u0131s\u0131 uzakla\u015ft\u0131r\u0131l\u0131r. Dondurucu on \u00fc\u00e7 saat boyunca 4,5 kW net kapasite sa\u011fl\u0131yorsa, 58,5 kWh \u0131s\u0131 uzakla\u015ft\u0131r\u0131l\u0131r. Bu de\u011ferleri, tahmini g\u00fcnl\u00fck \u0131s\u0131 transferi, hava s\u0131z\u0131nt\u0131s\u0131, \u00fcr\u00fcn, fan, ayd\u0131nlatma ve buz \u00e7\u00f6zme \u0131s\u0131s\u0131 ile kar\u015f\u0131la\u015ft\u0131r\u0131n. Beygir g\u00fcc\u00fc yerine, ger\u00e7ek \u00e7al\u0131\u015fma ko\u015fullar\u0131nda nominal so\u011futma kapasitesini kullan\u0131n.<\/p>\n<p>LINBLE&#8217;\u0131n <a href=\"https:\/\/www.linble-coldroom.com\/tr\/soguk-oda-yogusmali-unitesi\/\"><u>so\u011fuk oda yo\u011fu\u015fma \u00fcnitesi se\u00e7enekleri<\/u><\/a>, so\u011futucu ve dondurucu gereksinimlerini kar\u015f\u0131lar; ancak ekipman boyutu tek ba\u015f\u0131na \u00e7al\u0131\u015fma s\u00fcresini belirleyemez.<\/p>\n<h2>Kap\u0131 Trafi\u011fini ve Ortam S\u0131cakl\u0131\u011f\u0131n\u0131 Test Edin<\/h2>\n<p>Kap\u0131 hareketlili\u011fi, hem hissedilebilir \u0131s\u0131 kazanc\u0131n\u0131 hem de nem s\u0131z\u0131nt\u0131s\u0131n\u0131 de\u011fi\u015ftirir. Daha s\u0131cak d\u0131\u015f hava, yal\u0131t\u0131ml\u0131 paneller aras\u0131ndaki s\u0131cakl\u0131k fark\u0131n\u0131 art\u0131r\u0131r ve kondansat\u00f6r\u00fcn daha elveri\u015fsiz ko\u015fullarda \u00e7al\u0131\u015fmas\u0131na neden olabilir. Dondurucularda nemli hava, buz \u00e7\u00f6zme ihtiyac\u0131n\u0131 art\u0131rabilir.<\/p>\n<p>Keyfi y\u00fczde art\u0131\u015flar\u0131 uygulamak yerine, etkilenen bile\u015fenleri yeniden hesaplay\u0131n.<\/p>\n<table>\n<tbody>\n<tr>\n<td>\u00d6rnek \u00e7al\u0131\u015fma durumu<\/td>\n<td>So\u011futucu kWh\/g\u00fcn<\/td>\n<td>Dondurucu kWh\/g\u00fcn<\/td>\n<\/tr>\n<tr>\n<td>Referans: 30\u00b0C ortam s\u0131cakl\u0131\u011f\u0131; 12 a\u00e7ma \u00d7 45 saniye<\/td>\n<td>27,84<\/td>\n<td>63,14<\/td>\n<\/tr>\n<tr>\n<td>Yo\u011fun trafikli kap\u0131: 30\u00b0C; 40 a\u00e7\u0131l\u0131\u015f \u00d7 60 s<\/td>\n<td>33,14<\/td>\n<td>75,28<\/td>\n<\/tr>\n<tr>\n<td>S\u0131cak ortam: 40\u00b0C; 12 a\u00e7\u0131l\u0131\u015f \u00d7 45 s<\/td>\n<td>37,99<\/td>\n<td>83,04<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Yo\u011fun giri\u015f varsay\u0131mlar\u0131:<\/strong> So\u011futucu kompres\u00f6r \u00e7al\u0131\u015fma s\u00fcresi 8 saatten 10 saate; dondurucu \u00e7al\u0131\u015fma s\u00fcresi 13 saatten 16 saate \u00e7\u0131kar. Dondurucunun elektrikli buz \u00e7\u00f6zme s\u00fcresi 1,5 saatten 2 saate \u00e7\u0131kar, bu da evaporat\u00f6r fan\u0131n\u0131n \u00e7al\u0131\u015fma s\u00fcresini 22 saate d\u00fc\u015f\u00fcr\u00fcr. Bile\u015fenlerin g\u00fc\u00e7 de\u011ferleri ise de\u011fi\u015fmez. Bunlar, \u00f6l\u00e7\u00fclen sonu\u00e7lar de\u011fil, modelleme yoluyla elde edilen \u00e7al\u0131\u015fma s\u00fcresi de\u011fi\u015fiklikleridir.<\/p>\n<p><strong>Y\u00fcksek ortam s\u0131cakl\u0131\u011f\u0131 varsay\u0131mlar\u0131:<\/strong> So\u011futucu kompres\u00f6r\u00fcn\u00fcn elektrik giri\u015fi 11 saat boyunca 2,60 kW&#8217;a; dondurucunun giri\u015fi ise 17 saat boyunca 3,70 kW&#8217;a y\u00fckselir. Kondenser fan g\u00fc\u00e7leri s\u0131ras\u0131yla 0,25 ve 0,30 kW olarak kal\u0131r; di\u011fer programlar temel seviyede kal\u0131r. Bu senaryo, ek kap\u0131 trafi\u011fini kapsamaz.<\/p>\n<p>\u00d6rne\u011fin, s\u0131cak hava ko\u015fullar\u0131nda so\u011futucunun toplam t\u00fcketimi (2,60 \u00d7 11) + (0,25 \u00d7 11) + 5,28 + 0,40 + 0,96 = 37,99 kWh\/g\u00fcnd\u00fcr. Dondurucu i\u00e7in de benzer \u015fekilde toplam 83,04 kWh\/g\u00fcn elde edilir. Ekipman e\u011frileri ve tesis ko\u015fullar\u0131yla kar\u015f\u0131la\u015ft\u0131rarak do\u011frulay\u0131n.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-15498\" src=\"https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Include-Product-Turnover-Before-Trusting-the-Estimate.webp\" alt=\"Include Product Turnover Before Trusting the Estimate\" width=\"900\" height=\"600\" srcset=\"https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Include-Product-Turnover-Before-Trusting-the-Estimate.webp 900w, https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Include-Product-Turnover-Before-Trusting-the-Estimate-300x200.webp 300w, https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Include-Product-Turnover-Before-Trusting-the-Estimate-768x512.webp 768w, https:\/\/www.linble-coldroom.com\/wp-content\/uploads\/2026\/11\/Include-Product-Turnover-Before-Trusting-the-Estimate-600x400.webp 600w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/p>\n<h2>Tahmine G\u00fcvenmeden \u00d6nce \u00dcr\u00fcn Devir H\u0131z\u0131n\u0131 Dikkate Al\u0131n<\/h2>\n<p>10 tonluk \u00f6nceden so\u011futulmu\u015f sto\u011fu depolamak, her g\u00fcn 10 tonluk \u00fcr\u00fcn\u00fc so\u011futmak veya dondurmakla ayn\u0131 \u015fey de\u011fildir. S\u0131cak gelen \u00fcr\u00fcnler, \u00fcr\u00fcn y\u00fck\u00fcn\u00fc ve kompres\u00f6r \u00e7al\u0131\u015fma s\u00fcresini art\u0131r\u0131r.<\/p>\n<p>Faz de\u011fi\u015fimi olmayan hissedilebilir so\u011futma i\u00e7in:<\/p>\n<p><strong>\u00dcr\u00fcn \u0131s\u0131s\u0131 (kWh termal) = k\u00fctle (kg) \u00d7 \u00f6zg\u00fcl \u0131s\u0131 (kJ\/kg\u00b7\u00b0C) \u00d7 s\u0131cakl\u0131k de\u011fi\u015fimi (\u00b0C) \u00f7 3.600<\/strong><\/p>\n<p>\u00d6rnek bir hesaplama olarak, her g\u00fcn 1.000 kg so\u011futulmu\u015f \u00fcr\u00fcn\u00fcn 15\u00b0C s\u0131cakl\u0131kta geldi\u011fini ve +5\u00b0C&#8217;ye ula\u015fmas\u0131 gerekti\u011fini varsayal\u0131m. 3,8 kJ\/kg\u00b7\u00b0C \u00f6zg\u00fcl \u0131s\u0131 varsay\u0131ld\u0131\u011f\u0131nda, uzakla\u015ft\u0131r\u0131lmas\u0131 gereken ek \u0131s\u0131 10,56 kWh termal olur. \u00d6rnek so\u011futucunun varsay\u0131lan 5,0 kW net kapasitesinde, kapasite de\u011fi\u015fmezse bu yakla\u015f\u0131k 2,11 saatlik ek kompres\u00f6r \u00e7al\u0131\u015fma s\u00fcresi anlam\u0131na gelir.<\/p>\n<p>Kompres\u00f6r ve kondenser fan\u0131n\u0131n her ikisi de \u00e7al\u0131\u015f\u0131rken, bu yakla\u015f\u0131k (2,40 + 0,25) \u00d7 2,11 = 5,59 kWh\/g\u00fcn ek y\u00fck anlam\u0131na gelir. Bu art\u0131\u015f \u00f6rnek niteli\u011findedir.<\/p>\n<p>\u221212\u00b0C&#8217;de 1.000 kg \u00f6nceden dondurulmu\u015f \u00fcr\u00fcn alan bir dondurucu, \u00f6zg\u00fcl \u0131s\u0131 1,9 kJ\/kg\u00b7\u00b0C olarak varsay\u0131l\u0131rsa, \u221218\u00b0C&#8217;ye ula\u015fmak i\u00e7in yakla\u015f\u0131k 3,17 kWh termal \u0131s\u0131y\u0131 uzakla\u015ft\u0131r\u0131r. Dondurulmam\u0131\u015f \u00fcr\u00fcnlerin dondurulmas\u0131 gizli \u0131s\u0131 ekler; \u015fok dondurma i\u00e7in depolama b\u00fct\u00e7esini kullanmay\u0131n.<\/p>\n<h2>Tahminleri \u0130\u015fletme Verileriyle De\u011fi\u015ftirin<\/h2>\n<p>Ayl\u0131k enerji b\u00fct\u00e7esini onaylamadan \u00f6nce, ger\u00e7ek ekipman i\u00e7in bir y\u00fck program\u0131 ve bir elektrik program\u0131 talep edin. Biri \u0131s\u0131 kazanc\u0131n\u0131 belirler; di\u011feri ise elektrik y\u00fcklerini tan\u0131mlar.<\/p>\n<ul>\n<li><strong><b>Stok profilini <\/b><\/strong><b><\/b><strong><b>do\u011frulay\u0131n:<\/b><\/strong> Maksimum stok miktar\u0131, g\u00fcnl\u00fck devir h\u0131z\u0131, gelen \u00fcr\u00fcnlerin s\u0131cakl\u0131klar\u0131 ve dondurma i\u015fleminin odan\u0131n i\u00e7inde ger\u00e7ekle\u015ftirilip ger\u00e7ekle\u015ftirilmedi\u011fi.<\/li>\n<li><strong><b>Muhafaza alan\u0131n\u0131 <\/b><\/strong><b><\/b><strong><b>kaydedin:<\/b><\/strong> \u0130\u00e7 boyutlar, panel ve zemin yap\u0131s\u0131, kap\u0131 boyutu, contalar, kurulum yeri ve \u00e7evre s\u0131cakl\u0131klar\u0131.<\/li>\n<li><strong><b>Elektrik giri\u015flerini <\/b><\/strong><b><\/b><strong><b>belirtin:<\/b><\/strong> Yaln\u0131zca kompres\u00f6r g\u00fcc\u00fc ile t\u00fcm \u00fcnitenin g\u00fcc\u00fc, kondenser ve evaporat\u00f6r fan motorlar\u0131, buz \u00e7\u00f6zme \u0131s\u0131t\u0131c\u0131s\u0131, kap\u0131 \u0131s\u0131t\u0131c\u0131lar\u0131 ve kontroller.<\/li>\n<li><strong><b>\u00c7al\u0131\u015fma s\u0131ralar\u0131n\u0131 <\/b><\/strong><b><\/b><strong><b>belgelendirin:<\/b><\/strong> Kompres\u00f6r \u00e7al\u0131\u015ft\u0131rmalar\u0131, fan gecikmeleri, kap\u0131 a\u00e7\u0131lmalar\u0131, buz \u00e7\u00f6zme i\u015fleminin ba\u015flamas\u0131 ve sona ermesi ile mevsimsel ayar noktalar\u0131.<\/li>\n<li><strong><b>Devreye alma i\u015fleminden sonra <\/b><\/strong><b><\/b><strong><b>\u00f6l\u00e7\u00fcm yap\u0131n:<\/b><\/strong> So\u011fuk oda devrelerini alt saya\u00e7larla \u00f6l\u00e7\u00fcn, en az yedi temsil edici g\u00fcn\u00fcn verilerini kaydedin ve g\u00fcnl\u00fck kWh de\u011ferlerini kap\u0131 a\u00e7\u0131lma say\u0131lar\u0131, \u00fcr\u00fcn teslimatlar\u0131 ve ortam s\u0131cakl\u0131\u011f\u0131 ile kar\u015f\u0131la\u015ft\u0131r\u0131n.<\/li>\n<\/ul>\n<p>Mevsimsel tahminler i\u00e7in daha uzun s\u00fcreli kay\u0131tlar kullan\u0131n. Saya\u00e7 toplam\u0131 ekipman toplam\u0131ndan y\u00fcksekse, genel bir verimlilik kayb\u0131 atfetmeden \u00f6nce \u00f6ncelikle atlanm\u0131\u015f \u0131s\u0131t\u0131c\u0131lar, beklenmedik \u00e7al\u0131\u015fma saatleri veya payla\u015f\u0131lan devreler olup olmad\u0131\u011f\u0131n\u0131 kontrol edin.<\/p>\n<p>LINBLE&#8217;\u0131n <a href=\"https:\/\/www.linble-coldroom.com\/tr\/soguk-oda-elektrik-gereksinimleri-ekipman-teslimatindan-once-kontrol-edilmesi-gerekenler\/\"><u>so\u011fuk oda elektrik gereksinimleri kontrol listesi,<\/u><\/a> al\u0131c\u0131lar\u0131n teklifte yaln\u0131zca kompres\u00f6r de\u011feri belirtildi\u011finde kolayca g\u00f6zden ka\u00e7an devreleri tespit etmelerine yard\u0131mc\u0131 olur.<\/p>\n<h2>LINBLE ile 10 Tonluk So\u011fuk Oda Maliyetinizi Hesaplay\u0131n<\/h2>\n<p>Bu varsay\u0131lan depolama senaryosunda, +5\u00b0C&#8217;lik oda g\u00fcnde 27,84 kWh, \u221218\u00b0C&#8217;lik dondurucu ise g\u00fcnde 63,14 kWh t\u00fcketir. Bunlar varsay\u0131lan sonu\u00e7lard\u0131r, garantili de\u011ferler de\u011fildir.<\/p>\n<p>LINBLE, depolama s\u0131cakl\u0131\u011f\u0131, boyutlar, yal\u0131t\u0131m, kap\u0131lar ve so\u011futma ekipman\u0131na g\u00f6re <a href=\"https:\/\/www.linble-coldroom.com\/tr\/soguk-oda\/\"><u>\u00f6zel so\u011fuk odalar<\/u><\/a> tasarlar. \u00dcr\u00fcn i\u015fleme kapasitenizi, yerel ortam s\u0131cakl\u0131\u011f\u0131 aral\u0131\u011f\u0131n\u0131z\u0131 ve elektrik tarifesini payla\u015farak projeye \u00f6zel y\u00fck hesaplamas\u0131 ve elektrikli ekipman listesi talep edebilirsiniz.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>10 tonluk bir so\u011fuk oda, so\u011futulmu\u015f mu yoksa dondurulmu\u015f mu \u00fcr\u00fcnler depolad\u0131\u011f\u0131na ba\u011fl\u0131 olarak \u00e7ok farkl\u0131 miktarlarda elektrik t\u00fcketebilir. \u00d6nemli [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":15492,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[91],"tags":[],"class_list":["post-15538","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized-tr"],"_links":{"self":[{"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/posts\/15538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/comments?post=15538"}],"version-history":[{"count":2,"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/posts\/15538\/revisions"}],"predecessor-version":[{"id":15540,"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/posts\/15538\/revisions\/15540"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/media\/15492"}],"wp:attachment":[{"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/media?parent=15538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/categories?post=15538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.linble-coldroom.com\/tr\/wp-json\/wp\/v2\/tags?post=15538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}